Postavímedům 775 654 443

Vapour-open or vapour-closed wall

A vapour-open assembly contains no vapour barrier and water vapour can pass through it towards the outside. A vapour-closed assembly has a vapour-tight layer on the inner face that limits vapour diffusion into the structure. Both work. They differ in what their reliability rests on and in what happens when something goes wrong on site.

A window opening in a stud frame, surrounded by a breather membrane
A window opening meeting the envelope. This is one of the places where leaks most often start.

Section through a vapour-open wall

Layers in order from interior to exterior. Thicknesses depend on the design and on the thermal assessment, so we do not state them here.
Plasterboard on service battens The service cavity carries wiring and pipes, so nobody drills through the airtight layer to fit a socket. Insulation in the service cavity Adds thermal resistance and protects the airtight layer from damage during fit-out. OSB board Braces the wall and, in a vapour-open assembly, also forms the airtight layer. Joints are taped. KVH load-bearing studs The structure itself. The space between studs is filled with insulation, usually mineral wool or blown cellulose. Wood fibre board External insulation across the studs. It reduces thermal bridging and summer overheating and still lets vapour out. Render or ventilated cladding Keeps rain out. In a vapour-open assembly the outer layer must not be vapour-tight, which is why polystyrene is not used here.

InteriorExterior

The difference between the two

Vapour-open against vapour-closed external wall assembly.
AspectVapour-openVapour-closed
Vapour barrierNone. Vapour passes through and the structure can dry towards the outside.Present, usually a plastic film on the inner face.
Airtight layerFormed by the board materials on the inner side, typically OSB with taped joints, which also brace the wall.Usually the vapour barrier itself, taped and connected to every adjoining detail.
What you must not doClose the wall from outside with a layer of higher vapour resistance. That is why polystyrene is not used.Puncture the film or leave a joint untaped. A local leak can lead to condensation inside the structure.
Sensitivity to workmanshipMore tolerant of a small mistake, because the structure has somewhere to dry to.Function depends on a perfectly executed vapour barrier.
Typical materialsMineral wool or blown cellulose between the studs, wood fibre board outside, breathable render or ventilated cladding. Insulation between the studs, a vapour-tight film, OSB and an external insulation system.

When each one fits

A vapour-open assembly makes sense when you want a structure that forgives a small mistake and can dry out, and when render on wood fibre board or ventilated cladding suits you. It is often chosen for low energy houses, where polystyrene would not be used anyway.

A vapour-closed assembly makes sense when you want a conventional external insulation system, you have a company that can install and connect the film reliably, and you want a thinner wall for the same thermal resistance.

What is risky in both cases is mixing elements of the two systems without a thermal assessment. A vapour barrier inside and wood fibre board outside is not a problem in itself; polystyrene on a vapour-open wall is.

Airtightness matters equally in both

Leaks in the envelope affect heat loss, the moisture behaviour of the structure and the durability of the timber. Airtightness is therefore verified by measurement, a blower door test, ideally while the joints are still accessible. A test after the finishes are on will tell you where you stand, but the repairs are expensive by then.

The usual leak points are window junctions, service penetrations, the wall to ceiling junction and the corners. That is why services run in a service cavity and not through the airtight layer.

Frequently asked questions

Does vapour-open mean the wall breathes?

Not in the way people usually mean. Air does not flow through the wall; the wall has to be airtight. Only water vapour moves through it by diffusion, which is a slow process. Air change in the house has to come from ventilation, whether windows or a heat recovery system. A vapour-open assembly is not a substitute for ventilation.

Can a house with a vapour barrier be just as good?

Yes. A vapour-closed assembly is a proven, common solution and works long term when it is executed carefully. It is simply more sensitive to detail: its reliability rests on the film being continuous, taped and connected to every penetration.

Can you tell the type of assembly on a finished house?

Not reliably from the outside. You find it in the design documentation and in the material delivery notes. That is why we recommend having the assembly written into the quote and keeping the documentation. It pays off in a later refurbishment and when you sell.

Send us your brief

The more specific the brief, the more specific the answer. It helps to know whether you already have a design, what state the plot is in, and whether you want a turnkey house or only the shell.

We pass your enquiry to a building company that works in your area. If we have none there, we say so straight away instead of leaving you waiting.

Prefer to call? 775 654 443

Only the e-mail is required. The more you write, the more specific our answer is.